AGA Classic eR7 Repair & Service
All-electric cast-iron AGA with capacitance touch-screen control and full independent control of all five cooking zones. Replaced the AGA Total Control.
- Current model
- Fuel: electric
- Controls: TEK PCB
- 3 models
Overview
AGA Classic eR7 overview
All-electric cast-iron AGA with capacitance touch-screen control and full independent control of all five cooking zones. Replaced the AGA Total Control.
Replaced the AGA Total Control in the AGA lineup.
Configuration
- Width (in)
- 39
- Ovens
- 3
- Hotplates
- 2
- Zones
- boiling plate (hotspot), simmer plate, roast oven, baking oven, simmer oven
- Oven Settings
- Roast Oven R9, R8, R7, R6, B4; Baking Oven B1, B2, B3, B4; Simmer Oven preset
- Preset Temps
- Boiling Plate (°C) 330; Boiling Plate (°F) 626; Simmer Plate (°C) 200; Simmer Plate (°F) 392
Technical
- Hotplate Element kW
- 2.5
- Oven Element kW
- 2.5
- Element Resistance Ohm
- 18–22
- Total Connected kW
- 17.5
- Supply
- 240V 60Hz, 30A dedicated circuit, factory-fitted NEMA 14-50P plug
- Power Sharing
- PCB limits to three active elements at any one time so a 30A supply is sufficient despite ~76A of connected load
- Element Note
- Boiling plate and simmer plate use the same 2.5kW circular element. All three ovens use the same 2.5kW rectangular element part number; roast and bake ovens have two (roof + base), simmer oven has one (base) driven at 50% power by the PCB.
- Thermocouples
- Duplex type, identical for every cooking zone. 4 wires at the plug; each thermocouple is one green + one white conductor. TCU rear is marked BO / HS / SS / SO / RO.
Lineup
AGA Classic eR7 models
Known issues
Common AGA Classic eR7 problems
What goes wrong on this series and how we fix it.
Diagnostics
AGA Classic eR7 error codes
Fault and indicator codes for the AGA Classic eR7 control platform.
- 002 — Com WD Fault (communication watchdog)
- 003 — Com WD Fault (communication watchdog)
- 004 — Not used
- 005 — Not used
- 006 — WD WDT Fault (watchdog timer)
- 007 — TC Ref Fault — the user panel PCB is unable to process thermocouple measurements
- 010-014 — Full power time out — the cooking zone is taking too long to reach its expected temperature. This is a safety feature, not necessarily a component failure.
- 020-024 — Thermocouple differential — the two thermocouples in a zone disagree
- 060-100 — Thermocouple open circuit
- 110-116 — Relay short circuit
- 120-124 — Cooking zone overheat error
- 130-136 — Triac fault
- 139 — User panel overheat — excessive temperatures recorded at the control panel
- 140 — Configuration key fault
- 150-156 — Relay open circuit
- 159 — RF fault — receiver not communicating with the PCB
- CE — No response from main controller
- FE — Touch panel microcontroller unresponsive or malfunctioned
- VE — Main controller firmware version incompatible
Parts
Key AGA Classic eR7 parts
The parts this series actually needs — with OEM numbers and diagnostic tests.
Frequently asked questions
What are the most common AGA Classic eR7 problems?
The issues we see most on the AGA Classic eR7: aGA oven door rope seal worn — heat loss, poor cooking, hot fascia; aGA oven or hotplate element failed (no heat / reduced heat); aGA full power time-out (codes 010–014) — zone too slow to reach temperature. Each has a dedicated repair guide on this site.
How much does AGA Classic eR7 repair cost?
Every visit starts with diagnostics and a written estimate — the diagnostic fee applies toward your repair when you proceed. We never start work without your approval.
Book your AGA repair
Same-day and next-day appointments across the Seattle–Tacoma metro. Diagnostic fee applies toward your repair.
Mon–Sun 8:00AM–8:00PM
Independent service company — not affiliated with or authorized by AGA / AGA Rangemaster (Middleby). We repair out-of-warranty AGA appliances.