## What you will notice

- Yellow or lifting flames
- Sooting
- Burners far too small or far too large
- Poor oven performance on propane

## What is usually behind it

- Wrong orifices for the gas type (most common)
- Gas regulator not switched for LP (common)
- Incorrect LP supply pressure (common)

## How a technician diagnoses it

1. Elise 48 orifice reference (natural gas / LP, in units used by the service manual): centre burner 205 / 118, right front burner 112 / 68. See the manual's full orifice table for all burners.
2. Remove burner heads and undo the large brass nuts to change orifices.
3. Access the gas regulator by removing the storage drawer.
4. Confirm LP supply pressure is correct for proper operation.

> ⚠️ **Safety first:** LP conversion must be done by a licensed technician with a manometer. Never mix orifice sets.

## Parts usually needed

- [Burner orifice / injector (natural gas and LP sets)](https://aga.repair/aga-range-burner-orifice-replacement) (gas)
- [Range gas pressure regulator](https://aga.repair/aga-range-gas-regulator-replacement) (gas)

## Appliances affected

- [AGA Elise](https://aga.repair/aga-elise-repair)
- [AGA Legacy](https://aga.repair/aga-legacy-repair)
- [AGA Mercury](https://aga.repair/aga-mercury-repair)
- [AGA Professional](https://aga.repair/aga-professional-repair)

> ⚠️ **Safety & DIY disclaimer:** guides on this site are for information only. Appliance repair involves 240V electricity, gas connections, refrigerant and heavy cast-iron parts — anything you do yourself is at your own risk and can damage the appliance or cause injury. The safe option is to book a qualified technician.

## Related AGA problems

- [Gas oven will not heat — bake ignitor glows but the gas valve never opens](https://aga.repair/aga-range-bake-ignitor-weak)
- [Range burner lights then goes out when the knob is released](https://aga.repair/aga-range-burner-wont-stay-lit)
- [Range cooktop burners will not spark, or spark continuously](https://aga.repair/aga-range-no-spark)

## Frequently asked questions

### Can I fix this myself?

Professional repair only. This fault involves gas or 240V electrical components — diagnosis and repair should be done by a licensed technician.

### How much does it cost to fix this issue?

Every visit starts with diagnostics and a written estimate — the diagnostic fee applies toward your repair when you proceed. We never start work without your approval.

---

## Book a repair

- Call or text: 206-427-7323 (Mon–Sun 8:00AM–8:00PM, Pacific Time)
- Book online: https://aga.repair/contact/
- Email: service@aga.repair
- Service at your home across the Seattle–Tacoma metro, WA. Diagnostic fee applies toward your repair.

Independent service company — not affiliated with or authorized by AGA / AGA Rangemaster (Middleby). We repair out-of-warranty AGA appliances.