# AGA ERA Repair & Service

> AGA ERA repair at your home — cast iron range specialists. Models: AGA ERA. OEM parts, written warranty. Mon–Sun 8:00AM–8:00PM. Call or text 206-427-7323.

Newest AGA cast-iron line for North America. Handset/app-driven control with preset oven settings (R6 etc.) and an induction hob option. Error codes are reported on the handset.

## AGA ERA overview

Newest AGA cast-iron line for North America. Handset/app-driven control with preset oven settings (R6 etc.) and an induction hob option. Error codes are reported on the handset.

## AGA ERA models

- [AGA ERA](https://aga.repair/aga-aga-era-repair) — Current model

## Common AGA ERA problems

- [AGA oven door rope seal worn — heat loss, poor cooking, hot fascia](https://aga.repair/aga-door-rope-seal) (Very common)
- [AGA full power time-out (codes 010–014) — zone too slow to reach temperature](https://aga.repair/aga-full-power-timeout) (Common)
- [Induction hob will not detect the pan / E6 cookware fault](https://aga.repair/aga-induction-cookware) (Common)
- [Induction hob shows E2 — electronics too hot](https://aga.repair/aga-induction-e2-overheat) (Common)
- [One cooking zone on an electric AGA is dead or the zone lights flash rapidly](https://aga.repair/aga-tek-zone-dead) (Common)
- [AGA thermocouple open circuit or drifting](https://aga.repair/aga-thermocouple-open) (Common)
- [AGA communication cable / CE code — no response from main controller](https://aga.repair/aga-comms-cable) (Occasional)
- [AGA main PCB (TEK/Tekelek) failure](https://aga.repair/aga-pcb-triac) (Occasional)

## AGA ERA error codes

- [002 — Com WD Fault (communication watchdog)](https://aga.repair/aga-error-code-002)
- [003 — Com WD Fault (communication watchdog)](https://aga.repair/aga-error-code-003)
- [004 — Not used](https://aga.repair/aga-error-code-004)
- [005 — Not used](https://aga.repair/aga-error-code-005)
- [006 — WD WDT Fault (watchdog timer)](https://aga.repair/aga-error-code-006)
- [007 — TC Ref Fault — the user panel PCB is unable to process thermocouple measurements](https://aga.repair/aga-error-code-007)
- [010-014 — Full power time out — the cooking zone is taking too long to reach its expected temperature. This is a safety feature, not necessarily a component failure.](https://aga.repair/aga-error-code-010-014)
- [020-024 — Thermocouple differential — the two thermocouples in a zone disagree](https://aga.repair/aga-error-code-020-024)
- [060-100 — Thermocouple open circuit](https://aga.repair/aga-error-code-060-100)
- [110-116 — Relay short circuit](https://aga.repair/aga-error-code-110-116)
- [120-124 — Cooking zone overheat error](https://aga.repair/aga-error-code-120-124)
- [130-136 — Triac fault](https://aga.repair/aga-error-code-130-136)
- [139 — User panel overheat — excessive temperatures recorded at the control panel](https://aga.repair/aga-error-code-139)
- [140 — Configuration key fault](https://aga.repair/aga-error-code-140)
- [150-156 — Relay open circuit](https://aga.repair/aga-error-code-150-156)
- [159 — RF fault — receiver not communicating with the PCB](https://aga.repair/aga-error-code-159)
- [CE — No response from main controller](https://aga.repair/aga-error-code-ce)
- [E2 — The electronic unit is too hot](https://aga.repair/aga-error-code-e2)
- [E6 — Cookware / load fault (AGA ERA)](https://aga.repair/aga-error-code-e6)
- [Er + number — Internal technical fault that cannot be rectified by the user](https://aga.repair/aga-error-code-er-plus-number)
- [FE — Touch panel microcontroller unresponsive or malfunctioned](https://aga.repair/aga-error-code-fe)
- [(no display operation) — Over-voltage or loss of supply voltage to the range](https://aga.repair/aga-error-code-no-display-operation)
- [U400 — The range has been incorrectly connected (supply wiring fault)](https://aga.repair/aga-error-code-u400)
- [VE — Main controller firmware version incompatible](https://aga.repair/aga-error-code-ve)

## Key AGA ERA parts

- [AGA COMS communication cable (PCB to fascia)](https://aga.repair/aga-comms-cable-replacement) (wiring)
- [AGA customer RF handset](https://aga.repair/aga-handset-replacement) (control)
- [AGA induction generator module](https://aga.repair/aga-induction-generator-replacement) (control)
- [AGA oven element (eR7, 2.5 kW rectangular)](https://aga.repair/aga-oven-element-replacement) (heating)
- [AGA rope seal (door ropes and top plate element rope seal)](https://aga.repair/aga-rope-seal-replacement) (seal)
- [AGA main TEK / Tekelek PCB (complete tray)](https://aga.repair/aga-tek-pcb-replacement) (control)
- [AGA duplex thermocouple (eR7 platform)](https://aga.repair/aga-thermocouple-replacement) (sensor)

## Frequently asked questions

### What are the most common AGA ERA problems?

The issues we see most on the AGA ERA: aGA oven door rope seal worn — heat loss, poor cooking, hot fascia; aGA full power time-out (codes 010–014) — zone too slow to reach temperature; induction hob will not detect the pan / E6 cookware fault. Each has a dedicated repair guide on this site.

### How much does AGA ERA repair cost?

Every visit starts with diagnostics and a written estimate — the diagnostic fee applies toward your repair when you proceed. We never start work without your approval.

---

## Book a repair

- Call or text: 206-427-7323 (Mon–Sun 8:00AM–8:00PM, Pacific Time)
- Book online: https://aga.repair/contact/
- Email: service@aga.repair
- Service at your home across the Seattle–Tacoma metro, WA. Diagnostic fee applies toward your repair.

Independent service company — not affiliated with or authorized by AGA / AGA Rangemaster (Middleby). We repair out-of-warranty AGA appliances.