# AGA Classic R7 Repair & Service

> AGA Classic R7 repair at your home — cast iron range specialists. Models: R7 100, R7 150, R7 210. OEM parts, written warranty. Mon–Sun 8:00AM–8:00PM. Call or text 206-427-7323.

Always-on radiant-heat electric AGA. Ovens run 24/7 as a heat store; hotplates switch on and off. Boiling and simmer plates are controlled by mechanical liquid-filled thermostats with overheat protection on the neutral side; ovens are PCB + thermocouple controlled.

## AGA Classic R7 overview

Always-on radiant-heat electric AGA. Ovens run 24/7 as a heat store; hotplates switch on and off. Boiling and simmer plates are controlled by mechanical liquid-filled thermostats with overheat protection on the neutral side; ovens are PCB + thermocouple controlled.

### Configuration

- **Width (in):** 39
- **Ovens:** 3
- **Hotplates:** 2
- **Oven Names Na:** roasting, baking, slow cook (called simmering in the UK)
- **Temperatures:** Boiling Plate (°C) 340; Boiling Plate (°F) 644; Simmer Plate (°C) 240; Simmer Plate (°F) 464; Roast Oven (°C) 230; Roast Oven (°F) 446; Baking Oven (°C) 175; Baking Oven (°F) 347; Slow Cook Oven (°C) 115; Slow Cook Oven (°F) 239

### Technical

- **Hotplate Element kW:** 2.5
- **Oven Element kW:** 1.75
- **Oven Element Resistance Ohm:** 30
- **Low Energy Setting:** true

## AGA Classic R7 models

- [R7 100](https://aga.repair/aga-r7-100-repair) — Current model
- [R7 150](https://aga.repair/aga-r7-150-repair) — Current model
- [R7 210](https://aga.repair/aga-r7-210-repair) — Current model

## Common AGA Classic R7 problems

- [AGA oven door rope seal worn — heat loss, poor cooking, hot fascia](https://aga.repair/aga-door-rope-seal) (Very common)
- [AGA oven or hotplate element failed (no heat / reduced heat)](https://aga.repair/aga-element-open) (Very common)
- [AGA hotplate not reaching temperature (mechanical thermostat models)](https://aga.repair/aga-hotplate-thermostat) (Common)
- [AGA thermocouple open circuit or drifting](https://aga.repair/aga-thermocouple-open) (Common)
- [AGA insulation degradation — long heat-up, high running cost, low hotplate output](https://aga.repair/aga-insulation-loss) (Occasional)
- [AGA insulating lid will not sit level / lid hinge worn](https://aga.repair/aga-lid-hinge) (Occasional)
- [AGA R7 oven running hot or cold (oven thermocouple / PCB control)](https://aga.repair/aga-oven-thermocouple) (Occasional)
- [AGA overheat cut-out tripping](https://aga.repair/aga-overheat-cutout-trip) (Occasional)
- [AGA hotcupboard / warming module not heating](https://aga.repair/aga-hotcupboard-element) (Rare)
- [AGA external vent fan not running or noisy](https://aga.repair/aga-vent-fan) (Rare)

## Key AGA Classic R7 parts

- [AGA boiling plate thermostat (liquid-filled)](https://aga.repair/aga-boiling-plate-thermostat-replacement) (control)
- [AGA thermocouple conduit sealing bung / plug](https://aga.repair/aga-conduit-bung-replacement) (seal)
- [AGA hotcupboard element (400W boost / 200W maintain)](https://aga.repair/aga-hotcupboard-element-replacement) (heating)
- [AGA boiling / simmer plate element](https://aga.repair/aga-hotplate-element-replacement) (heating)
- [AGA loose-fill and block insulation](https://aga.repair/aga-insulation-replacement) (structural)
- [AGA insulating lid hinge assembly](https://aga.repair/aga-lid-hinge-assy-replacement) (mechanical)
- [AGA hotplate overheat cut-out (manually resettable)](https://aga.repair/aga-overheat-cutout-replacement) (safety)
- [AGA R7 main PCB](https://aga.repair/aga-r7-main-pcb-replacement) (control)
- [AGA R7 oven element replacement kit (1.75 kW)](https://aga.repair/aga-r7-oven-element-kit-replacement) (heating)
- [AGA R7 oven overheat cut-out](https://aga.repair/aga-r7-oven-overheat-replacement) (safety)
- [AGA R7 oven thermocouple](https://aga.repair/aga-r7-oven-thermocouple-replacement) (sensor)
- [AGA rope seal (door ropes and top plate element rope seal)](https://aga.repair/aga-rope-seal-replacement) (seal)
- [AGA simmer plate thermostat (liquid-filled)](https://aga.repair/aga-simmer-plate-thermostat-replacement) (control)
- [AGA external vent fan](https://aga.repair/aga-vent-fan-replacement) (motor)

## Frequently asked questions

### What are the most common AGA Classic R7 problems?

The issues we see most on the AGA Classic R7: aGA oven door rope seal worn — heat loss, poor cooking, hot fascia; aGA oven or hotplate element failed (no heat / reduced heat); aGA hotplate not reaching temperature (mechanical thermostat models). Each has a dedicated repair guide on this site.

### How much does AGA Classic R7 repair cost?

Every visit starts with diagnostics and a written estimate — the diagnostic fee applies toward your repair when you proceed. We never start work without your approval.

---

## Book a repair

- Call or text: 206-427-7323 (Mon–Sun 8:00AM–8:00PM, Pacific Time)
- Book online: https://aga.repair/contact/
- Email: service@aga.repair
- Service at your home across the Seattle–Tacoma metro, WA. Diagnostic fee applies toward your repair.

Independent service company — not affiliated with or authorized by AGA / AGA Rangemaster (Middleby). We repair out-of-warranty AGA appliances.