# AGA Classic eR7 Repair & Service

> AGA Classic eR7 repair at your home — cast iron range specialists. Models: eR7 100, eR7 150, eR7 210. OEM parts, written warranty. Mon–Sun 8:00AM–8:00PM. Call or text 206-427-7323.

All-electric cast-iron AGA with capacitance touch-screen control and full independent control of all five cooking zones. Replaced the AGA Total Control.

## AGA Classic eR7 overview

All-electric cast-iron AGA with capacitance touch-screen control and full independent control of all five cooking zones. Replaced the AGA Total Control.

Replaced the **AGA Total Control** in the AGA lineup.

### Configuration

- **Width (in):** 39
- **Ovens:** 3
- **Hotplates:** 2
- **Zones:** boiling plate (hotspot), simmer plate, roast oven, baking oven, simmer oven
- **Oven Settings:** Roast Oven R9, R8, R7, R6, B4; Baking Oven B1, B2, B3, B4; Simmer Oven preset
- **Preset Temps:** Boiling Plate (°C) 330; Boiling Plate (°F) 626; Simmer Plate (°C) 200; Simmer Plate (°F) 392

### Technical

- **Hotplate Element kW:** 2.5
- **Oven Element kW:** 2.5
- **Element Resistance Ohm:** 18–22
- **Total Connected kW:** 17.5
- **Supply:** 240V 60Hz, 30A dedicated circuit, factory-fitted NEMA 14-50P plug
- **Power Sharing:** PCB limits to three active elements at any one time so a 30A supply is sufficient despite ~76A of connected load
- **Element Note:** Boiling plate and simmer plate use the same 2.5kW circular element. All three ovens use the same 2.5kW rectangular element part number; roast and bake ovens have two (roof + base), simmer oven has one (base) driven at 50% power by the PCB.
- **Thermocouples:** Duplex type, identical for every cooking zone. 4 wires at the plug; each thermocouple is one green + one white conductor. TCU rear is marked BO / HS / SS / SO / RO.

## AGA Classic eR7 models

- [eR7 100](https://aga.repair/aga-er7-100-repair) — Current model
- [eR7 150](https://aga.repair/aga-er7-150-repair) — Current model
- [eR7 210](https://aga.repair/aga-er7-210-repair) — Current model

## Common AGA Classic eR7 problems

- [AGA oven door rope seal worn — heat loss, poor cooking, hot fascia](https://aga.repair/aga-door-rope-seal) (Very common)
- [AGA oven or hotplate element failed (no heat / reduced heat)](https://aga.repair/aga-element-open) (Very common)
- [AGA full power time-out (codes 010–014) — zone too slow to reach temperature](https://aga.repair/aga-full-power-timeout) (Common)
- [One cooking zone on an electric AGA is dead or the zone lights flash rapidly](https://aga.repair/aga-tek-zone-dead) (Common)
- [AGA thermocouple open circuit or drifting](https://aga.repair/aga-thermocouple-open) (Common)
- [AGA communication cable / CE code — no response from main controller](https://aga.repair/aga-comms-cable) (Occasional)
- [AGA insulation degradation — long heat-up, high running cost, low hotplate output](https://aga.repair/aga-insulation-loss) (Occasional)
- [AGA insulating lid will not sit level / lid hinge worn](https://aga.repair/aga-lid-hinge) (Occasional)
- [AGA main PCB (TEK/Tekelek) failure](https://aga.repair/aga-pcb-triac) (Occasional)
- [AGA user panel overheat (code 139)](https://aga.repair/aga-user-panel-overheat) (Occasional)
- [AGA configuration key fault (code 140)](https://aga.repair/aga-config-key) (Rare)
- [AGA hotcupboard / warming module not heating](https://aga.repair/aga-hotcupboard-element) (Rare)
- [AGA external vent fan not running or noisy](https://aga.repair/aga-vent-fan) (Rare)

## AGA Classic eR7 error codes

- [002 — Com WD Fault (communication watchdog)](https://aga.repair/aga-error-code-002)
- [003 — Com WD Fault (communication watchdog)](https://aga.repair/aga-error-code-003)
- [004 — Not used](https://aga.repair/aga-error-code-004)
- [005 — Not used](https://aga.repair/aga-error-code-005)
- [006 — WD WDT Fault (watchdog timer)](https://aga.repair/aga-error-code-006)
- [007 — TC Ref Fault — the user panel PCB is unable to process thermocouple measurements](https://aga.repair/aga-error-code-007)
- [010-014 — Full power time out — the cooking zone is taking too long to reach its expected temperature. This is a safety feature, not necessarily a component failure.](https://aga.repair/aga-error-code-010-014)
- [020-024 — Thermocouple differential — the two thermocouples in a zone disagree](https://aga.repair/aga-error-code-020-024)
- [060-100 — Thermocouple open circuit](https://aga.repair/aga-error-code-060-100)
- [110-116 — Relay short circuit](https://aga.repair/aga-error-code-110-116)
- [120-124 — Cooking zone overheat error](https://aga.repair/aga-error-code-120-124)
- [130-136 — Triac fault](https://aga.repair/aga-error-code-130-136)
- [139 — User panel overheat — excessive temperatures recorded at the control panel](https://aga.repair/aga-error-code-139)
- [140 — Configuration key fault](https://aga.repair/aga-error-code-140)
- [150-156 — Relay open circuit](https://aga.repair/aga-error-code-150-156)
- [159 — RF fault — receiver not communicating with the PCB](https://aga.repair/aga-error-code-159)
- [CE — No response from main controller](https://aga.repair/aga-error-code-ce)
- [FE — Touch panel microcontroller unresponsive or malfunctioned](https://aga.repair/aga-error-code-fe)
- [VE — Main controller firmware version incompatible](https://aga.repair/aga-error-code-ve)

## Key AGA Classic eR7 parts

- [AGA COMS communication cable (PCB to fascia)](https://aga.repair/aga-comms-cable-replacement) (wiring)
- [AGA thermocouple conduit sealing bung / plug](https://aga.repair/aga-conduit-bung-replacement) (seal)
- [AGA PCB electrical supply configuration key](https://aga.repair/aga-config-key-replacement) (control)
- [AGA customer RF handset](https://aga.repair/aga-handset-replacement) (control)
- [AGA hotcupboard element (400W boost / 200W maintain)](https://aga.repair/aga-hotcupboard-element-replacement) (heating)
- [AGA boiling / simmer plate element](https://aga.repair/aga-hotplate-element-replacement) (heating)
- [AGA loose-fill and block insulation](https://aga.repair/aga-insulation-replacement) (structural)
- [AGA insulating lid hinge assembly](https://aga.repair/aga-lid-hinge-assy-replacement) (mechanical)
- [AGA oven element (eR7, 2.5 kW rectangular)](https://aga.repair/aga-oven-element-replacement) (heating)
- [AGA rope seal (door ropes and top plate element rope seal)](https://aga.repair/aga-rope-seal-replacement) (seal)
- [AGA Touch Control Unit (customer user panel)](https://aga.repair/aga-tcu-replacement) (control)
- [AGA main TEK / Tekelek PCB (complete tray)](https://aga.repair/aga-tek-pcb-replacement) (control)
- [AGA duplex thermocouple (eR7 platform)](https://aga.repair/aga-thermocouple-replacement) (sensor)
- [AGA external vent fan](https://aga.repair/aga-vent-fan-replacement) (motor)

## Frequently asked questions

### What are the most common AGA Classic eR7 problems?

The issues we see most on the AGA Classic eR7: aGA oven door rope seal worn — heat loss, poor cooking, hot fascia; aGA oven or hotplate element failed (no heat / reduced heat); aGA full power time-out (codes 010–014) — zone too slow to reach temperature. Each has a dedicated repair guide on this site.

### How much does AGA Classic eR7 repair cost?

Every visit starts with diagnostics and a written estimate — the diagnostic fee applies toward your repair when you proceed. We never start work without your approval.

---

## Book a repair

- Call or text: 206-427-7323 (Mon–Sun 8:00AM–8:00PM, Pacific Time)
- Book online: https://aga.repair/contact/
- Email: service@aga.repair
- Service at your home across the Seattle–Tacoma metro, WA. Diagnostic fee applies toward your repair.

Independent service company — not affiliated with or authorized by AGA / AGA Rangemaster (Middleby). We repair out-of-warranty AGA appliances.